Author: admin
Video de operación del incinerador de desechos a pequeña escala
islands incinerators
Application : four islands in Croatia Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day Burning temperature – over 12000C Two chambers – minimum Emissions – dioxin and heavy metaly – better then Kyoto protocol Emission – monitoring system Waste unloiding – directly from waste track to incinerator Burn Rate(Average kgs/hr) 25 kg primary chamber 800 degree secondary chamber 1000 degree chimney standard shredder separately Autoclave or microwaves separately temperature monitor attached outside of machine operating Fuel and electric – Toxic and dangerous wastes, – Medical pharmaceutical and hospitable liquids Wastes – Domestic garbage – Electric and electronic wastes – Industrial wastes – In General, all type of wastes and garbages 1) working now in new order for Nigeria though our company for Yd-300 x 2 units , this is a job in hand in our customer located in dubai 2) the customer also want also to buy a fuel bulk storage tank to be for 3 days continuous operation so we hope also you can manufacture it so please give me the best price for fuel bulk storage tank to be for 3 days continuous operation for YD-300 3) installation must be in the site in Nigeria by your company ,as i know your price rate which you sent to be before 4) what is the best price CIF Nigeria in lagos sea port as i have only price for cif dubai 5) 150 pcs Waste Containers (820 L) fully compatible with the incinerator and clinical waste container washing system. please send me the price and catalog for this item 6) also they need Automatic Clinical Waste Container Washing System complete in every respect and fully compatible with containers price and catalog 7) 2 units 1.5 tonne Fork Lift ( if you know good price and quality company in china) 8) 1 unit Clinical Waste Container Vehicles complete in every respect and fully compatible with containers. 9) Spare Parts For 2 Years Operation & Maintenance for YD-300 and for the above machines 10) all parts , pipe work electrical work and civil work for incinerator must be provided and material must be quoted The highest temperature that the filter bag can operate continuously is 260C. In order to add a bag house using our filter products, you would need to add a water cooling tower or other method to reduce the inlet temperature at the baghouse to less than 260C. If you cannot lower the temperature below 260C, then we cannot utilize our membrane filter bags.
incineradores para instalar na ilha de Aruba
incineradores a instalar na ilha de Aruba. a ilha não tem resíduos médicos e outros incineradores de resíduos. estamos no processo de explorar a viabilidade e montar uma instalação de incineração na ilha de Aruba. esta é uma ilha de 120.000 habitantes. temos 2 hospitais, mais de 20 consultórios odontológicos e mais de 50 consultórios…
L'autre jour dans l'usine d'incinération des déchets
Récemment, un rêve est devenu réalité pour moi. J’ai eu l’occasion de participer à une visite guidée de l’usine d’incinération de déchets de Cologne. Cela peut paraître étrange. Parfois je me surprends quand je suis coincé sur des programmes documentaires sur les méthodes de recyclage dans le (rare) zapping à travers les chaînes de télévision….
new hospital waste treatment plant
We are in the process of building a new hospital waste treatment plant and we are evaluating different technologies from around the world. We are looking to incinerate approx. 1 to 2 tons of biomedical waste per day using LPG for heating. Please send me all general information and quotes for machines of all ranges that could meet our needs. Also, please include emissions reports of all of the various machines that could be of interest to us especially with regards to dioxins and furals as well as lists of recommendations from past clients. If you have any government entities using your machines please include lists of whom they are as well as any documentation that you contain that can prove their use. Timing is also very important to us with regards of when the machines can arrive to Peru and be up and running. Therefore, it would be appreciated if you could include time frames and the whole process from purchase to installation and maintenance. Burning Rate:5–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash pot 100kg:Max 3.8kg
incineradores médicos en china
¿Las operaciones de la planta estarían operativas las 24 horas del día, los 7 días de la semana, todo el año excepto periodos de mantenimiento regular y preventivo? ¿Cuántas horas al año podría estar operativo su proceso? ¿Cuál sería su enfoque para proyectos más grandes con el objetivo de valorizar 1000 toneladas por día? ¿Cuánta…
Система управления лабораторными отходами 01. Система очистки сжиженной воды.
new hospital waste treatment plant
We are in the process of building a new hospital waste treatment plant and we are evaluating different technologies from around the world. We are looking to incinerate approx. 1 to 2 tons of biomedical waste per day using LPG for heating. Please send me all general information and quotes for machines of all ranges that could meet our needs. Also, please include emissions reports of all of the various machines that could be of interest to us especially with regards to dioxins and furals as well as lists of recommendations from past clients. If you have any government entities using your machines please include lists of whom they are as well as any documentation that you contain that can prove their use. Timing is also very important to us with regards of when the machines can arrive to Peru and be up and running. Therefore, it would be appreciated if you could include time frames and the whole process from purchase to installation and maintenance. Burning Rate:5–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash pot 100kg:Max 3.8kg
"Guida utente inceneritore"
Guida utente inceneritore





